Alexor PC9155D-433 Guia de Instalação Página 11

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 10
2 Installation
2-3
2.2 Wiring
1. I/O Wiring
The two I/O terminals can be programmed as hard-wired zone inputs and/or PGM outputs. See programming section [013] Opt [1,2].
1a. Zone Wiring
Zones 1 - 32 are reserved for wireless zones. If programmed as zone inputs, I/O-
1 is zone 33 and I/O-2 is zone 34.
Zones can be wired for Normally Open (NO) contacts with single-end-of-line
resistors or Normally Closed (NC) contacts with single-end-of-line or double-
end-of-line resistors.
Observe the following guidelines.
For UL/ULC listed installations use SEOL or DEOL only
Use minimim 22AWG, maximum 18 AWG wire
DO NOT use shielded wire
Wire run resistance shall not exceed 100
Zones 33 and 34 are defaulted for SEOL resistors
Programming section [133]-[134] opt.[14] selects Normally Closed or
Normally Open
Programming section [133-[134] opt.[15] selects SEOL resistors
Programming section [133]-[134] opt.[16] selects DEOL resistors
Zone Status - Loop Resistance/Loop Status (DEOL only)
Fault - 0
(shorted wire/loop)(shorted wire to 4.5KOhm)
Secure - 5,600
(contact closed)(4.5KOhm to 6.25KOhm)
Violated - 11,200
(contact open)(13.5KOhm to open)
Tamp er - infinite (broken wire, open)(9KOhm to 13.5KOhm)
1b. Programmable Output (PGM) and Aux Wiring
I/O terminals configured as Programmable Outputs (PGMs) switch to ground
when activated by the alarm system. The PGMs are open collector outputs.
With a 45 mA load, the voltage measured at the PGM and Aux + shall be
approximately 8V with respect to ground. With a 25 mA load, the voltage mea-
sured shall be approximately 10V.
Connect the positive side of the device to the Aux+ terminal.
Connect the negative side of the device to the I/O terminal.
Each PGM can provide 50mA maximum output.
NOTE: The alarm system can provide 200mA maximum of AUX current for
PGMs, relays, LEDs etc.
The AUX output shall be used only for residential burglary applications.
LED output with:
Current limiting resistor and
optional relay driver output.
Compatible initiating devices intended
to be used on the AUX output shall be
rated for the range: 9.6VDC to
13.8VDC min.
Normally Closed Loops - Do NOT use for UL Installations
Any I/O
Terminal
Double End-of-Line Resistor Wiring
AUX-
Terminal
2 NORMALLY CLOSED
CONTACTS WITH
NO END OF LINE
RESISTOR
1 NORMALLY CLOSED
CONTACT WITH
NO END OF LINE
RESISTOR
Single End-of-Line Resistor Wiring
1 NORMALLY
CLOSED
CONTACT WITH
5600Ω
END OF LINE
RESISTOR
1 NORMALLY OPEN
CONTACT WITH
5600 Ω
END OF LINE RESITSTOR
1 NORMALLY OPEN
CONTACT AND
1 NORMALLY CLOSED
CONTACT WITH
5600Ω END OF LINE
RESISTOR
2 NORMALLY OPEN
CONTACTS AND
2 NORMALLY CLOSED
CONTACTS WITH
5600Ω END OF LINE
RESISTOR
A
LARM
CONTACT
DEOL CIRCUIT
1 NORMALLY
CLOSED CONTACT
WITH 5600Ω
END OF LINE RESISTORS
ALARM
CONTACT
DEOL CIRCUITS
2 NORMALLY
CLOSED CONTACTS
WITH 5600Ω END
OF LINE & TAMPER
RESISTOR
TEMPER
CONTACT
Any I/O
Terminal
Any I/O
Terminal
Any I/O
Terminal
Any I/O
Terminal
Any I/O
Terminal
Any I/O
Terminal
Any I/O
Terminal
AUX-
Terminal
AUX-
Terminal
AUX-
Terminal
AUX-
Terminal
AUX-
Terminal
AUX-
Terminal
AUX-
Terminal
Burglary Zone Wiring Chart
Wire Size Max wire length to end-of-line resistor
AWG mm Feet Meters
22 0.65 3000 914
20 0.81 4900 1493
19 0.91 6200 1889
18 1.02 7800 2377
Figures are based on maximum wiring resistance of 100 Ω
I/O
I/O