Alexor PC9155D-433 Guia de Instalação

Consulte online ou descarregue Guia de Instalação para Sistemas de segurança - controlo de acesso Alexor PC9155D-433. Alexor PC9155D-433 Installation guide [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Models:
PC9155-433/868
PC9155G-433/868
PC9155D-433/868
Used with:
WT5500-433/868
WT5500P-433/868
Series 2-way Wireless Keypad
IMPORTANT: This manual contains information on limitations regarding product use and function and information
on the limitations as to liability of the manufacturer. The entire manual should be carefully read.
v1.0 Installation Guide
2-Way Wireless Security Suite
These DSC Security Alarm
Systems may be connected
to the Telecom Network
PTC 211 / 09 /017 PC9155-433
PTC 211 / 09 /019 PC9155G-433
TELEPERMIT
RN =
0.5
PTC 211 / 09 /018 PC9155D-433
N11427
Vista de página 0
1 2 3 4 5 6 ... 87 88

Resumo do Conteúdo

Página 1 - Used with:

Models: PC9155-433/868 PC9155G-433/868 PC9155D-433/868Used with: WT5500-433/868 WT5500P-433/868 Series 2-way Wireless KeypadIMPORTANT: This

Página 2

PC9155 Wireless Alarm System2-2 Figure 2-3 Mounting & Wiring Details Phone Line T1-Brn Connects to in-house phone lineR1- Gra Connects to in-house

Página 3 - CO Detectors

2 Installation2-32.2 Wiring1. I/O WiringThe two I/O terminals can be programmed as hard-wired zone inputs and/or PGM outputs. See programming section

Página 4 - WARNING - READ CAREFULLY

PC9155 Wireless Alarm System2-42.3 Wireless Device EnrollmentInstalling a one-way or two-way wireless device requires programming the system with the

Página 5 - Table of Contents

2 Installation2-5Enroll wireless devices in the following sequence:• Keypad• Sirens• Sensors• Pendants• Wireless KeysRefer to the associated installat

Página 6 - 1 Introduction

PC9155 Wireless Alarm System2-6Enrolling Sensors & Pendants Step1Enter [*][8][5555][898] “Wireless Enrollment Mode” is displayed.Step2• Place the

Página 7 - Ready to Arm

2 Installation2-72.4 Global Wireless Device Placement Test2.5 Individual Wireless Device Placement TestWireless Device PlacementPerform the Wireless D

Página 8 - Special Keys:

PC9155 Wireless Alarm System2-82.6 GPRS/Ethernet Module Setup/InitializationStep 2Enter a 2 digit zone number, keypad number, or siren number dependin

Página 9

3 Operation3-13 Operation3.1 Operating Modes3.1.1 – Away ArmingAway Arming arms the entire system including the perimeter and interior devices. The Re

Página 10 - FUSEFUSE

PC9155 Wireless Alarm System3-2[][1] – Bypass/Re-activate Stay/Away and Night ZonesPress [][1] to enter Bypass mode. If the Code Required for Bypas

Página 11 - 2 Installation

3 Operation3-3[][6] – User FunctionsTo access the User Functions section, press [][6] followed by the master or supervisor code. Select one of the f

Página 12

i SAFETY INSTRUCTIONS FOR SERVICE PERSONNELWARNING: WHEN USING EQUIPMENT CONNECTED TO THE TELEPHONE NETWORK, THERE ARE BASIC SAFETY INSTRUCTIONS THAT

Página 13

PC9155 Wireless Alarm System3-4[][7][1 or 2] – Command Outputs (1&2)Press [][7] then [1] or [2]. If the Command Output Code Required option is e

Página 14

4 Programming4-14 ProgrammingThe PC9155 can be programmed using three methods:• Template Programming - Allows the minimum required data to be programm

Página 15 - Select Device <>

PC9155 Wireless Alarm System4-2• Digit 1 selects one of the following zone definition options for the first 8 zones. A ‘0’ in the digit 1 locationindi

Página 16

4 Programming4-3• Digit 2 selects one of the following reporting code options:• Digit 3 selects one of the following options:Digit 3 - Table Headings

Página 17 - 3 Operation

PC9155 Wireless Alarm System4-4Digit 4 indicates/selects one of the following DLS connections:4.2 DLS Programming4.2.1 Local Programming with PC-LinkF

Página 18 - PC9155 Wireless Alarm System

5 Installer Programming5-15 Installer Programming5.1 Index to Programming OptionsSect Description

Página 19 - [][6] – User Functions

PC9155 Wireless Alarm System5-25.2 Programming WorksheetsDefNACPEU00 Null Zone 14 Future Use 28 Future Use01 Delay 1 15 24-Hour Medical 29 Future Use0

Página 20 - 3.4 Function Keys

5 Installer Programming5-3 For 4-digit codes the default is the first 4 digits00 Null PGM (Not Used) TLM and Alarm01 Fire and Burglary Output For Futu

Página 21 - 4 Programming

PC9155 Wireless Alarm System5-4NA CP EUON OFF1999 [F] Key Enabled  [F] Key Disabled2 [P] Key Audible (Siren / Beeps)  [P] Key Silent3999 Quick Ex

Página 22 - Enter Hex Data

5 Installer Programming5-5Zone Type33 Future Use35 Future Use99999934 Future Use929 Future Use26 24-Hour Non-Alarm (local alarm)99911 24-Hour Burglary

Página 23

iiKuva 1MakuuhuoneMakuuhuoneMakuuhuoneOlohuoneKeittiöGuidelines for Locating Smoke & CO DetectorsThe following information is for general guidance

Página 24 - 4.3 Installer Programming

PC9155 Wireless Alarm System5-6NA CP EU NA CP EU[202] Zone 1-8 [203] Zone 9-16 [204] Zone 17-24 [205] Zone 25-32 [206] Zone 33-34NA CP EU NA CP EU NA

Página 25 - 5 Installer Programming

5 Installer Programming5-7Alarm CancelledFor Future UseKeypad [A]uxiliary AlarmKeypad [P]anic RestoreKeypad [F]ire RestoreCross Zone / Police Code Ala

Página 26 - 5.2 Programming Worksheets

PC9155 Wireless Alarm System5-8[330]-[332] Tam per Reporting Codes[338] Miscellaneous Tamper Reporting CodesKeypad Lockout[330]Zone 25Zone 33[341] Mis

Página 27

5 Installer Programming5-90000000000[346] Maintenance Restore Reporting CodesFor Future Use[345] Maintenance Alarm Reporting Codes[342] Opening (Disar

Página 28

PC9155 Wireless Alarm System5-10[350] Communicator Format Options1st Telephone Number 2nd Telephone Number 3rd Telephone Number 4th Telephone NumberCP

Página 29

5 Installer Programming5-11NA CP EUON OFF1999 Communications Enabled  Communications Disabled2 Restores On Siren Time-Out  Restores Follow Zones3

Página 30

PC9155 Wireless Alarm System5-12NA CP EUON OFF1 Answering Machine / Double Call Enabled Answ. Machine / Double Call Disabled2999 User Enable DLS 

Página 31

5 Installer Programming5-13*Attributes for Option 9 & 10 SectStart Time End TimeValid times areNA CP EUON OFF1 Tampers Enabled  Tampers Disabled

Página 32

PC9155 Wireless Alarm System5-14NA CP EUON OFF19 50 Hz AC Input  60 Hz AC Input2  Time Base is Internal Crystal  Time Base is AC Line3 AC/DC Armi

Página 33

5 Installer Programming5-15Sect.Value = Entry x 15 minutes. E.g., 6x15 minutes equals 1.5 hrs. Valid entries are 4-96 (1Hr - 24Hr)[082] [083] [084]

Página 34

Limited WarrantyDigital Security Controls warrants the original purchaser that for a period of twelve months from the date of purchase, the product sh

Página 35

PC9155 Wireless Alarm System5-16#5Def03Def04Def27Def30Def13Def14DefRefer to section [804][141]-[156] in the Programming Descriptions section of this g

Página 36

5 Installer Programming5-17NA CP EUON OFF1999 Siren Alarm Enabled  Siren Alarm Disabled299 Buzzer Notifications Enabled  Buzzer Notifications Disa

Página 37

PC9155 Wireless Alarm System5-18NA CP EUON OFF1  Ethernet Receiver #1 Supervised  Ethernet Receiver #1 Not Supervised2  GPRS Receiver #1 Supervised

Página 38

5 Installer Programming5-19OBF5 / 3061Valid Entries are 0000-2359, 9999 to disableValid Entries are 0000-2359, 9999 or FFFF to disable[851][223] GPRS

Página 39

PC9155 Wireless Alarm System5-20Enter 55 to restart the panel (unplug the power cable from the analogue module).[898] Wireless Device Enrollment See 2

Página 40

5 Installer Programming5-21 Enter [999][Installer Code][999] See Chapter 6.3 Resetting the System to Factory DefaultsFunction Key Options[00] Null Key

Página 41

PC9155 Wireless Alarm System5-22—NA CP EUON OFF1999 [F] Key Enabled  [F] Key Disabled2999 [A] Key Enabled  [A] Key Disabled3999 [P] Key Enabled 

Página 42

5 Installer Programming5-23NA CP EUON OFF1999 Local Clock Display Enabled  Local Clock Display Disabled2 Local Clock Displays 24 Hr Time  Local Cl

Página 43

PC9155 Wireless Alarm System5-245.3 Programming DescriptionsThis section describes all of the PC9155 programming options. [001]-[002] Zone Definitions

Página 44

5.3 Programming Descriptions5-25iThis zone type must NOT be used for wireless zones. Activation of a keyswitch zone is intended to arm or disarm the s

Página 45

ivTable of ContentsChapter Description Page1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 46

PC9155 Wireless Alarm System5-26[005] System Timers This section has two subsections. Entry/Exit delays are in subsection 01and Bell Cut-off is in sub

Página 47

5.3 Programming Descriptions5-27[012] Keypad Lockout Options This section determines how the keypad lockout function operates. • 24 hour supervisory b

Página 48 - [001]-[002] Zone Definitions

PC9155 Wireless Alarm System5-28[013] First System Options [014] Second System Options[015] Third System Options Option Description[1]ON: Zone 33/PG

Página 49

5.3 Programming Descriptions5-29[016] Fourth System Options [2]ON: Panic Key Audible. When a valid Panic key alarm is generated, the keypad buzz

Página 50 - [009] I/O Programming

PC9155 Wireless Alarm System5-30[018] Sixth System Options [023] Tenth System Options Code[024] Eleventh System Options Code Option Description[1]Fo

Página 51 - [012] Keypad Lockout Options

5.3 Programming Descriptions5-31[030] Zone Loop Response [101]-[134] Zone Attributes The following options can be enabled or disabled for each zone.

Página 52 - [015] Third System Options

PC9155 Wireless Alarm System5-32[167] GPRS/Ethernet Interface Communications Wait for ACK[168]-[169] Daylight Saving Time [170] PGM Output Timer[176]

Página 53

5.3 Programming Descriptions5-33 [301] First Telephone Number[302] Second Telephone Number[303] Third Telephone Number[304] Call Waiting Cancel Dialin

Página 54 - [018] Sixth System Options

PC9155 Wireless Alarm System5-34[328] Miscellaneous Alarm Reporting CodesDuress AlarmThis reporting code is transmitted whenever a Duress code is used

Página 55 - [101]-[134] Zone Attributes

5.3 Programming Descriptions5-35Exit FaultIf an Exit Error occurs and entry delay expires before the system is disarmed, this reporting code is sent.

Página 56

PC9155 Wireless Alarm System1-11 IntroductionThis manual provides installation and programming information for the PC9155 two-way wireless series of a

Página 57

PC9155 Wireless Alarm System5-36General Zone Fault & RestoreThis reporting code is sent whenever a zone has entered the fault state. This occurs w

Página 58

5.3 Programming Descriptions5-37Swinger Shutdown (Maintenance Troubles & Restores)This value determines the number of times the same system Mainte

Página 59

PC9155 Wireless Alarm System5-38[381] Second Communicator Options Code [382] Third Communicator Options Codei If all 5 attempts to the designated phon

Página 60

5.3 Programming Descriptions5-39[383] Fourth Communicator Options Code[389] GPRS/Ethernet Fault Check TimerThe programmed number of poll commands that

Página 61

PC9155 Wireless Alarm System5-40[402] Downloading Computer’s Telephone NumberThis phone number enables the control panel to call the downloading compu

Página 62

5.3 Programming Descriptions5-41[591]-[592] Inactivity TimersInactivity timers are used to create two windows to monitor 24-hr. non-alarm zone activit

Página 63

PC9155 Wireless Alarm System5-42[701] First International Options Code [702] Second International Options Code [703] Delay Between Dialing AttemptsFor

Página 64 - [499][Installers Code][499]

5.3 Programming Descriptions5-43[804]-[001]-[032] Wireless Device Serial NumberThese sections are for manual enrollment of one-way wireless device ser

Página 65

PC9155 Wireless Alarm System5-44[804][181]-[182] Wireless Key Enable/DisableThese sections enable each individual key enrolled on the system. The keys

Página 66

5.3 Programming Descriptions5-45[804][330] WT4911 Maximum Bell Activation TimeThis value determines the maximum time the wireless bell/siren will soun

Página 67

1 Introduction1-21.3 Controls & IndicatorsThe PC9155 can have a maximum of eight status indicators located on the front panel. The four indicators

Página 68

PC9155 Wireless Alarm System5-46[999] Restore Factory Default ProgrammingAll programming, including wireless device programming, returns to the factor

Página 69

5.3 Programming Descriptions5-47[001]-[069], [100]-[125] Label ProgrammingZone and other labels in these sections can be customized. Default labels ar

Página 70 - [] Keypad Programming

PC9155 Wireless Alarm System5-48[075] Second Keypad Options[076] Third Keypad Options[077] LCD MessageEnter a 32 character message. If anything other

Página 71

5.3 Programming Descriptions5-49[998] Initiate Global Label BroadcastProgrammed keypad labels are broadcast and installed on all system keypads from k

Página 72

PC9155 Wireless Alarm Panel6-16 Testing & Troubleshooting6.1 Wireless Device Placement TestSee sections 2.4 and 2.56.2 Testing the SystemInform th

Página 73 - ASCII Chart

6 Testing & Troubleshooting6-26.3 Resetting the System to Factory Defaults6.4 TroubleshootingResetting the alarm system returns it to the factory

Página 74 - Secure or

PC9155 Wireless Alarm Panel6-3[][2] Troubles • Power up system• Enter [][2] to view Troubles•Perform actions indicated in the tables below[][2] Tro

Página 75 - Ready to Arm <>

6 Testing & Troubleshooting6-4Trouble [2] AC FailureAC FailureNo AC at panel AC input terminals. • Verify voltage measured across AC terminals is

Página 76 - Trouble Cause Troubleshooting

PC9155 Wireless Alarm Panel6-56.5 Battery Removal/ReplacementDisconnect AC power and battery before proceeding.Removal: (1) Disconnect battery cable f

Página 77

Appendix A: Reporting Code FormatsAPP-1Appendix A: Reporting Code FormatsThe following tables contain Contact ID and Automatic SIA format reporting co

Página 78 - Replacement:

PC9155 Wireless Alarm System1-3Entering LettersSome commands require the entry of letters (i.e., A, B, C, D, E, F).To enter a letter, press and the

Página 79 - Contact ID

PC9155 Wireless Alarm PanelAPP-2Section #Reporting C o de C o de Sent WhenDialer DirectionAutomatic Contact ID CodesSIA Auto Rep Codes[346]Battery Tro

Página 80 - PC9155 Wireless Alarm Panel

Appendix A: Reporting Code FormatsAPP-3Section #Reporting C o de C o de Sent WhenDialer DirectionAutomatic Contact ID CodesSIA Auto Rep Codes[347]Keyp

Página 81

PC9155 Wireless Alarm PanelAPP-4Contact ID Programmed Zone Alarm/Restoral Event Codes(as per SIA DCS: ‘Contact ID’ 01-1999):Program any of these codes

Página 82 - Automatic Zone Alarm/Restoral

Appendix B: Communicator Format OptionsAPP-5Appendix B: Communicator Format OptionsThe following format options are programmable in section [350] 0102

Página 83

PC9155 Wireless Alarm PanelAPP-6Appendix C: 2-Way Audio Verification (PC5950)Not approved for use with UL/ULC listed installations.Audio Verification

Página 84 - The 2-way Audio Session

Appendix D: Regulatory Approvals InformationAPP-7Appendix D: Regulatory Approvals InformationNorth America FCC COMPLIANCE STATEMENTwill provide advanc

Página 85 - INDUSTRY CANADA STATEMENT

PC9155 Wireless Alarm PanelAPP-8This product has been tested and found in compliance with the following standards:UL1023 Household Burglar-Alarm Syste

Página 86

Appendix D: Regulatory Approvals InformationAPP-9SIA False Alarm Reduction InstallationsFor a list of the defaults value programmed when the unit is s

Página 87 - Programming Section

EuropeThis product is in conformity with:EMC Directive 2004/108/EC based on results using harmonized stan-dards in accordance with article 10(5), R&am

Página 88 - 29007510R003

2 Installation2-12 Installation2.1 Hardware InstallationHardware InstallationStep1Select a suitable location for the alarm panel in a dry location, cl

Comentários a estes Manuais

Sem comentários