PC9155 Wireless Alarm System
5-38
[381] Second Communicator Options Code
[382] Third Communicator Options Code
i
If all 5 attempts to the designated phone numbers fail, an FTC trouble for the primary phone number is initiated and logged to the event buffer regard-
less of how this option is configured.
[7]
For Future Use
[8]
ON: Delinquency Follows Zone Activity (Activity Delinquency). If there is no zone activity, the Delinquency Transmission Delay timer in section
[377] begins counting in hours. When the counter reaches the programmed time, the panel transmits the Delinquency Code, if programmed. If zone
activity is present on the system at any time, the counter is reset. If this option is used, the Closing Delinquency option is not available.
i
This code is not transmitted for panels that are “Away” armed.
Activity on bypassed zones do not affect this timer.
This timer is reset when armed.
OFF: Delinquency Follows Arming (Closing Delinquency). This reporting code is sent whenever the programmed number of days for delinquency
has expired without the panel being armed. The timer for this feature is programmed in section [377]. The value programmed in this section determines
the number of days the panel counts when not being armed before sending the delinquency reporting code to the central station. Once this code is sent,
the timer is not started again until the panel has been armed. This feature is disabled by programming 000 in section [377].
Option Description
[1]
ON: Opening After Alarm Keypad Ring-back Enabled. When the Opening After Alarm reporting code is successfully transmitted, the keypad
sounds a series of 8 beeps to confirm that the Opening After Alarm code was sent and received. This ring-back occurs for each Opening After Alarm
code successfully reported.
OFF: Opening After Alarm Keypad Ring-back Disabled. The keypad does not ring back when an opening after alarm is successfully transmitted.
[2]
For Future Use
[3]
ON: SIA Sends Programmed Rep. Codes. When this option is ON and there is a valid reporting code programmed in the reporting code section, the
programmed reporting code is transmitted.
i
If FF or 00 is programmed as a reporting code, the event is not communicated.
OFF: SIA Sends Automatic Rep. Codes. When this option is OFF the panel will transmit SIA automatic reporting codes. If the reporting code is pro-
grammed as 01-FE or FF the associated automatic reporting codes are transmitted. This option is used when a different reporting code is required (i.e.,
Residential Dial, etc). If 00 is programmed, reporting for the event is disabled. Refer to Appendix A: Reporting Code Formats.
[4]
ON: Closing Confirmation Enabled. When a Closing reporting code is successfully transmitted, the keypad sounds a series of 8 beeps to confirm that
the Closing code was sent and received.
OFF: Closing Confirmation Disabled. No keypad ring-back occurs when a Closing reporting code is successfully transmitted.
[5] [6]
For Future Use
[7]
ON: Contact I.D. Uses Programmed Reporting Codes. The Contact I.D. communications format uses programmed reporting codes when transmit-
ting to the central station.
OFF: Contact I.D. Uses Automatic Reporting Codes. The Contact I.D. communications format uses the automatic reporting codes as shown in
Appendix A when transmitting to the central station.
[8]
For Future Use
Option Description
[1]
For Future Use
[2]
ON: Zone Alarms Communicate during Walk Test Enabled. Zone alarms that occur during the walk test will communicate if programmed to do
so.
OFF: Zone Alarms Communicate during Walk Test Disabled. Zone alarms that occur during the walk test will not communicate even if pro-
grammed to do so.
[3]
ON: Communications Cancelled Message Enabled. The “Communications Cancelled” message is displayed if alarms are acknowledged during the
Transmission Delay time. This message is displayed for 5 seconds.
OFF: Communications Cancelled Message Disabled. The “Communications Cancelled” message is not displayed.
[4]
ON: Call Waiting Cancel Enabled. The call waiting dialing string programmed in section [304] is dialed before the first attempt of each phone num-
ber. All subsequent dialing attempts to the same phone number will not use the call waiting cancel dialing string.
OFF: Call Waiting Cancel Disabled. The call waiting dialing string will not be dialed.
[5]
ON: GPRS/Ethernet Module Enabled. PC-link support for DLS is disabled when this feature is ON. GPRS/Ethernet Module commands in accor-
dance with the current revision of the T-link Protocol are enabled for GS module support.
OFF: GPRS/Ethernet Module Disabled. PC-Link support for DLS is enabled when this feature is OFF. This includes auto-detect PC-Link. The
GPRS/Ethernet commands are also disabled.
Reporting Code Entry Option ON Option OFF
00 No Transmission No Transmission
FF No Transmission Auto Rep Code sent
01-FE 01-FE sent Auto Rep Code sent