Enrolling wireless detectors
Step 1 – Enter Quick Enroll ([*][8] + Installer Code + [898])
- the display will read ‘Wireless Enrollment Mode’
Step 2 – Trigger the detector
Door/window contact – activate tamper or violate contact
Motion detectors – activate tamper
Smoke Detector – activate tamper
Glassbreak Detector – activate tamper
Panic Pendant – Press and hold button for 2-3 seconds
CO Detector – activate tamper
Flood Sensor – activate tamper
- the display will indicate the serial of the detector triggered
Step 3 – Press [*] to confirm the correct device
Step 4 – The keypad will display the next available zone number, enter [*] to
accept. If a different zone is required enter the new 2-digit zone number (01 – 32)
Step 5 – The keypad will display the recommended zone definition, enter [*] to accept. If a
different definition is required, enter the new 2-digit zone definition and enter [*] to
accept
Step 6 – Repeat Steps 2-5 to enroll additional keypads
Notes:
- if the display does not indicate the serial number of the desired detector to be enrolled, press [#] and
repeat Step 2
- if the zone number entered in Step 4 is already occupied with a different serial number, the keypad will
prompt to enter [*] to replace with the new serial number or [#] to keep the previous device and return to the
zone number entry screen
Common Zone Definitions (refer to installation manual for a complete list)
[01] – Delay 1
[03] – Instant
[05] – Interior Stay/Away
[87] – Delayed 24 Hr Fire
[15] – 24 Hr. Medical
Comentários a estes Manuais