[*][6] – User Functions (Continued):
Option [8] – Late to Open Enable/Disable
When enabled, the control panel will report a ‘Late To Open’ reporting code to the central station if
the system is not disarmed before the time programmed in Option [9] is reached
Option [9] – Late to Open Time of Day
This option is used to specify the ‘Late to Open’ time
Step 1 – [*][6]+ [Master Code or Supervisory Code]
Step 2 – Press [9]
Step 3 – Press [1 -7] for the required day of the week (1 = Sunday)
Step 4 – Enter HH:MM (24 – hour format)
LCD Options:
Additional LCD options are available when access the ‘User Functions’. These options are as
following:
Event Buffer
Contrast *
Brightness *
Buzzer Volume*
* To adjust the options, use the keypad scroll buttons. When the desired option appears on the
display press the [*] button to select. Use the scroll buttons to select the desired level. Press [#] to
exit
Event Buffer:
Overview:
The event buffer stores the last 500 events generated on the system. These events include:
Alarms/Restores
Troubles
Tests
[*] Commands
Viewing Events:
Step 1 – [*][6]+ [Master Code or Supervisory Code]
Step 2 – Press [*] when ‘View Event Buffer’ is displayed
Step 3 – The display will show the most recent event (Event 001)
Each event is display in 2 separate levels:
Level 1 – displays the number of the event (The most recent event is 000),
followed by the partition label
Level 2 – displays the description of the events which occurred
Notes:
- pressing [*] at any time will toggle between level 1 and level 2 of an event.
- pressing the arrow keys (right/left) will scroll through events
- when a new event is logged, the oldest event stored will be erased