3 Operation
3-2
Re-activate Stay/Away and Night Zones:
Press [ ][1] when the system is armed in the Stay mode to change the armed status to Away mode or Night mode. The system will add the Stay/
Away zones back into the system after the exit delay time expires.
[ ][2] – Trouble Display
Refer to Chapter 6: Testing & Troubleshooting, for troubleshooting assistance and a detailed description of all trouble conditions.
[ ][3] – Alarm Memory Display
Pressing the scroll < > keys display an “Alarms in Memory” message if an alarm occurred during the last armed period. Pressing [ ][3] displays
the message “Scroll to view Alarms.” To clear the memory, arm then disarm the system.
[ ][4] – Door Chime Enable/Disable
Press [ ][4]. The keypad emits 3 rapid beeps to indicate that the door chime feature is enabled or a steady 2-second tone to indicate it is disabled.
The same function can be performed by pressing and holding the Chime function key for 2 seconds.
[ ][5] – Program User Codes
The following table identifies available user codes:
Programming User Codes
Press [ ][5] followed by the master code. The keypad displays the first user (user 01) and includes the letter “P” if the user code is programmed.
Scroll to the appropriate user number and press the [
] key to program the user (or enter the 2-digit user number). Enter a new 4 or 6-digit user
code or press [ ] to delete the user code. After the user code is programmed or deleted, scroll to another user number or press [#] to exit.
Programming User Attributes
Press [ ][5] followed by the master code or supervisor code. Press [9] followed by the 2-digit user number to view user attributes.
To change user attributes, press the number corresponding to the attribute or scroll to the desired attribute and press [
]. When the correct attri-
butes are assigned to the user, press [#] to exit. To change the attributes for another user, press [9] followed by the 2-digit user number. When fin-
ished, press [#] to exit.
i
If any zones are programmed as night zones (zone definition 37), pressing [ ][1] when the system is in Stay
mode activates Night mode instead of Away mode. Only night zones are bypassed. The stay and away zones
are added back into the system.
Code Type Function
[01] – [16]
[40]
General User Codes
Master Code
Determined by attributes programmed below
All attributes described below
i
Proximity tags can be assigned to a programmed user code on WT5500P keypads. After assigning a user code, the
display prompts for the tag to be swiped. This assigns a proximity tag to the user code. The user code will have a T in
the lower right hand corner indicating that a tag is associated with that code. To delete a proximity tag, the user code
must be deleted. Refer to the Proximity Tag Installation Sheet for details. The proximity tag can be used in place of
the access code for any of the instructions referred to in the Operation section of this manual.
i
• These attributes affect the operation of wireless keys.
• Wireless key numbers (01-16) correspond with user access codes (01-16).
• Duress codes are not valid when entering [ ][5], [ ][6] or [ ][8] sections.
• Duplicate codes and codes that are +/- 1 of an existing code can not be programmed.
[1] Supervisor’s Code: This attribute is used for validation when entering the [
][5] User Code Programming section and [ ][6] User
Functions section. Note, the supervisor’s code can only validate programming for codes with equal or lesser attributes. The
supervisor’s code also allows this user to create bypass groups if an access code is required to enter into [
][1] Bypassing.
[2] Duress Code: Duress codes are standard user codes that transmit the Duress Alarm Reporting Code whenever the code is entered to
perform any function on the system.
[3] Bypass Zones: The user can manually bypass zones if bypassing requires an access code.
[4] Phone Access: This attribute is used to specify which users can access the system remotely.
Note: After 5 invalid access codes, remote access is locked out. The invalid access codes timer is cleared every 60 minutes. Valid
access codes do not reset the invalid access code count.
[5-6] Future Use
[7] Bell Squawk On Arming/Disarming: The panel squawks the bell when the user arms using the Away function key and a user code,
or if the away function key is pressed on an identified wireless key.
[8] One-time Use Code: The one-time-use code allows unlimited arming but only permits a single disarming once a day. The Disarm
function is restored at midnight.