1 Introduction
1-2
1.3 Controls & Indicators
The PC9155 can have a maximum of eight status indicators located on the front panel. The four indicators located on the left side of the panel
indicate the Ready status, Armed status, Trouble status and AC Power status of the alarm system. Four additional indicators are located on the
right side of the panel only if a GS2065, TL265 or TL265GS module is installed. They indicate Communicator Trouble status, Network status
(TL265GS only), and High or Low signal strength.
Figure 1-1 Controls & Indicators - Keypad
1.4 Data Entry
Conventions Used
Brackets [ ] indicate numbers or symbols that are to be entered on the keypad.
E.g., [
][8][Installer Code][898] requires the following key entries:
[
] indicates to the alarm system that a special command will be entered.
[8] places the alarm system in Installer Programming mode.
[5555] is the default installer code. The default installer code should be changed during initial programming of the system.
[898] indicates the particular programming section being accessed.
E.g. [898] Wireless Device Enrollment, [899] Template Programming, [999] Alarm System Default
Entering Letters
Some commands require the entry of letters (i.e., A, B, C, D, E, F).
To enter a letter, press [
] and the number on the keypad that corresponds to the appropriate letter, as indicated below.
1=A, 2=B, 3=C, 4=D, 5=E, 6=F
The cursor will blink to indicate that you are entering letters. To revert back to numeric entry press [
].
Incorrect Data Entries:
To change a data entry before it has been accepted by the alarm system, use the scroll keys to reposition the cursor then re-enter the digit. If the
data has already been accepted by the system, press [#] to exit the section then re-enter the programming section and type the data again.
If you incorrectly enter 0001 in Step 2 of Program alarm system in Template Programming, you must either reset the alarm system to its default
values (section [996], re-enroll all wireless devices and re-program the system) or re-enter the correct data in Installer Programming [
][8].
Special Keys:
Scroll symbols < > on the display indicate that options can viewed by pressing the keys. These scroll keys can also be used to posi-
tion the cursor.
The key is similar in function to the “ENTER” key on a personal computer. It is generally used to accept the existing programming option.
It is also the first key entry for [ ] commands and can be used to enter the letters A-F when in Installer Programming mode.
The key functions similarly to the “ESCAPE” key on a personal computer. It is generally used to exit the current programming section or to
return to the previous menu.
Table 1-4 Controls & Indicators - Alarm Panel
Alarm Indicators GPRS/Ethernet Module Indicators
Ready: Panel is ready to be armed.
Armed: Panel is armed.
Trouble: Enter [][2] to view troubles.
Yellow indicates trouble. Orange indicates RF Jam trouble.
AC Power: On=AC present. OFF=AC absent.
Communicator Trouble: Enter [][2] to view troubles.
Network: Internet communication is absent.
Signal Strength (High): GPRS signal strength is high.
Signal Strength: (Low): GPRS signal strength is low.
System is
Ready to Arm
<>
Function
Keys
LED Indicators
Ready
Armed
Trouble
AC Power
Scroll Keys
Ambient Light
Sensor
LCD
Emergency Keys
Fire
Auxiliary
Panic
< > indicates user can
scroll through options
DG009033
1
23
4
5
6
7
89
0
#
*
,